In a photovoltaic tracking system, the controller is responsible for bracket angle adjustment, drive execution and operating‑status monitoring. The stability of power supply directly determines the continuous operation and O&M efficiency of the tracking system. As solar power stations grow in scale and application scenarios become increasingly complex, the power‑supply modes for tracker controllers have evolved from a single model to multiple technical routes.
![]()
Relationship Diagram of Power‑Supply Application for Solar Trackers
Power‑supply stability: Ensure continuous and reliable operation of controllers and drive systems.
Electrical safety: Mitigate risks introduced by high‑voltage access, circuit anomalies and electrical faults.
System compatibility: Adapt to different types of solar trackers, PV strings and station electrical architectures.
Environmental adaptability: Meet operational requirements under harsh outdoor conditions including high/low temperature, sand‑dust and high humidity.
O&M convenience: Reduce workload for on‑site construction, fault diagnosis and subsequent maintenance.
External AC power supply: Power is supplied to controllers and drive systems via AC power sources at the power station.
Self‑power supply: Electric energy is harvested from the photovoltaic system itself.
Electricity is fed from an external on‑site AC power source and converted to the operating voltage required by controllers and drive systems to enable solar tracker control and operation.
![]()
Stable power supply and simple maintenance. Power is sourced from the existing station grid and unaffected by lighting conditions. Normal operation is maintained on cloudy days, at night and under module shading. No additional energy‑storage batteries are required for maintenance. It performs well in low‑temperature environments and suits cold‑climate regions such as Russia and Northern Europe.
High capital investment: AC cables, power‑distribution equipment and cabling works raise upfront project costs.
Difficult construction: Larger‑scale stations and complex terrain increase challenges in circuit planning and field implementation.
Constrained power‑distribution conditions: Performance is subject to the station power‑distribution system, substation distance and on‑site power availability.
The self‑powered solution draws power directly from PV modules / strings. Electric energy passes through power‑conversion, isolation and protection circuits to provide operating power for tracking controllers and drive systems, with no dependence on external station AC power.
![]()
Focus areas: equipment configuration, lighting conditions and battery maintenance.
![]()
Focus areas: string compatibility, high‑voltage safety and power‑supply stability.
![]()
Focus areas: power‑tapping architecture, isolation design, system matching and operation & maintenance.
![]()
Differences among various power‑supply architectures lie not only in energy sources, but also in equipment configuration, construction constraints, electrical safety, system compatibility, after‑sales maintenance and many other dimensions. Therefore, evaluating a power‑supply solution calls for comprehensive analysis covering power source, system structure, operating conditions and practical application requirements.
Subsequent articles in this series will dive deep into the three self‑powered technical routes, elaborating on their working principles, technical features, application values and critical considerations.
| Upcoming Articles | Core Content |
|---|---|
| 02 | Small‑Module Self‑Powered Solution | Analyze features and limitations of standalone‑module power supply |
| 03 | Single‑Module Takeoff Solution | Discuss string compatibility and high‑voltage safety concerns |
| 04 | String Power Solution | Systematically introduce the architecture and application value of AITRACKER String Power |